Minimized site disturbance in design and construction

LEED CREDIT

ND-v2009 GIBc7: Minimized site disturbance in design and construction 1 point

LEEDuser’s viewpoint

Explore this LEED credit

Post your questions on this credit in the forum, and click on the credit language tab to review to the LEED requirements.

Credit language

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Requirements

OPTION 1. Development footprint on previously developed land
Locate 100% of the development footprint on areas that are previously developed and for which 100% of the construction impact zone is previously developed.

OR

OPTION 2. Undeveloped portion of project left undisturbed
Depending on the density of the project, do not develop or disturb a portion of the land that has not been previously developed on the site, exclusive of any land preserved by codified law or a prerequisite of LEED for Neighborhood Development; or exempt areas designated as nonbuildable in land-use comprehensive plans and stipulate in covenants, conditions, and restrictions (CC&R) or other binding documents that the undisturbed area will be protected from development in perpetuity. Densities and minimum percentages are as follows (mixed-use projects must use the lowest applicable density or calculate a weighted average per the methodology in NPD Credit 2, Compact Development):
Table 1. Minimum undeveloped area, by project density

Residential density (DU/acre)

Residential density (DU/hectare)

Nonresidential density (FAR)

Minimum area left undisturbed

20%

15 – 21

37 – 52

.50 – 1.0

15%

> 21

> 52

> 1.0

10%

DU = dwelling unit; FAR = floor-area ratio.

For portions of the site that are not previously developed, identify construction impact zones that limit disturbance to a minimum of 40 feet (12 meters) beyond the building perimeter; 10 feet (3 meters) beyond surface walkways, patios, surface parking and utilities less than 12 inches (300 millimeters) in diameter; 15 feet (4.5 meters) beyond street curbs and main utility branch trenches; and 25 feet (8 meters) beyond constructed areas with permeable surfaces (such as pervious paving areas, stormwater retention facilities, and playing fields) that require additional staging areas to limit compaction in the constructed zone.

AND

For all projects
Survey the site to identify the following:
  1. Trees in good or excellent condition, as determined by an arborist certified by the International Society of Arboriculture (ISA).
  2. Any heritage or champion trees of special importance to the community because of their age, size, type, historical association, or horticultural value, as defined by a government forester.
  3. All trees larger than 6 inches (150 millimeters) in diameter at breast height (dbh, 4 feet 6 inches [1.4 meters] above ground).
  4. Any invasive tree species present on the site, and whether those trees threaten the health of other trees to be preserved on the site, as determined by an ISA-certified arborist.
Preserve the following trees that are also identified as in good or excellent condition:
  1. All heritage or champion trees and trees whose dbh exceeds 50% of the state champion dbh for the species.
  2. A minimum of 75% of all noninvasive trees (including the above) larger than 18 inches (450 millimeters) dbh.
  3. A minimum of 25% of all noninvasive trees (including the above) larger than 12 inches (300 millimeters) dbh if deciduous, and 6 inches (150 millimeters) dbh if coniferous.
Tree condition ratings must be based on assessment by an ISA-certified arborist using ISA approved assessment measures. Develop a plan, in consultation with and approved by an ISA-certified arborist, for the health of the trees, including fertilization and pruning, and for their protection during construction. The plan must include protective fencing located 1 foot for (300 millimeters) each 1-inch (25 millimeter) caliper from the trunk or at the tree drip line, whichever is larger, and specify that if trenching or other disturbance is necessary within the protected zone, this work must be done by hand. If disturbance includes a permanent excavation of 3 feet (900 millimeters) or deeper, the excavation must start from a point not closer than 15 feet (4.5 meters) from the tree’s drip line. If an ISA-certified arborist has determined that any trees to be preserved are threatened by invasive vegetation, develop a plan to reduce the invasive vegetation to the maximum extent possible. Stipulate in CC&R or other binding documents that the undisturbed area of the preserved trees will be protected from development in perpetuity. See all forum discussions about this credit »

What does it cost?

Cost estimates for this credit

On each BD+C v4 credit, LEEDuser offers the wisdom of a team of architects, engineers, cost estimators, and LEED experts with hundreds of LEED projects between then. They analyzed the sustainable design strategies associated with each LEED credit, but also to assign actual costs to those strategies.

Our tab contains overall cost guidance, notes on what “soft costs” to expect, and a strategy-by-strategy breakdown of what to consider and what it might cost, in percentage premiums, actual costs, or both.

This information is also available in a full PDF download in The Cost of LEED v4 report.

Learn more about The Cost of LEED v4 »

Addenda

7/1/2014Updated: 2/14/2015
Global ACP
Description of change:
Table 1.
Add a second column, "Residential density (DU/hectare)," with the following values:
37 - 52
> 52
Campus Applicable
No
Internationally Applicable:
Yes
11/1/2011
LEED Interpretation
Inquiry:

The proposed project site is located on a military base that has potentially unexploded ordnance on-site.Protection from potential detonation during construction is required by the federal government to shield pedestrians and existing housing across the street from the project site. As a part of the project, a detonation barrier is to be constructed prior to start of excavation. This barrier can be built using various material but must have substantial foundations and structural strength to withstand large explosion forces. After construction is completed, the detonation barriers would be deconstructed to allow access to the site.The project team is proposing to incorporate salvaged local material into the design of these barrier walls. May the salvaged material qualify for MR credit 2 Construction Waste Managementif recycled after deconstruction?

Ruling:

The project team has inquired whether materials used for a temporary (during construction) detonation barrier can be included within the construction waste management materials diverted since it is mandated to be built. If the temporary detonation barrier is recycled or salvaged after deconstruction, it meets the intent of MR Credit 2 (diversion from landfill and incineration) and may contribute towards construction waste management.

Campus Applicable
No
Internationally Applicable:
No
See all forum discussions about this credit »

Documentation toolkit

The motherlode of cheat sheets

LEEDuser’s Documentation Toolkit is loaded with calculators to help assess credit compliance, tracking spreadsheets for materials, sample templates to help guide your narratives and LEED Online submissions, and examples of actual submissions from certified LEED projects for you to check your work against. To get your plaque, start with the right toolkit.

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Requirements

OPTION 1. Development footprint on previously developed land
Locate 100% of the development footprint on areas that are previously developed and for which 100% of the construction impact zone is previously developed.

OR

OPTION 2. Undeveloped portion of project left undisturbed
Depending on the density of the project, do not develop or disturb a portion of the land that has not been previously developed on the site, exclusive of any land preserved by codified law or a prerequisite of LEED for Neighborhood Development; or exempt areas designated as nonbuildable in land-use comprehensive plans and stipulate in covenants, conditions, and restrictions (CC&R) or other binding documents that the undisturbed area will be protected from development in perpetuity. Densities and minimum percentages are as follows (mixed-use projects must use the lowest applicable density or calculate a weighted average per the methodology in NPD Credit 2, Compact Development):
Table 1. Minimum undeveloped area, by project density

Residential density (DU/acre)

Residential density (DU/hectare)

Nonresidential density (FAR)

Minimum area left undisturbed

20%

15 – 21

37 – 52

.50 – 1.0

15%

> 21

> 52

> 1.0

10%

DU = dwelling unit; FAR = floor-area ratio.

For portions of the site that are not previously developed, identify construction impact zones that limit disturbance to a minimum of 40 feet (12 meters) beyond the building perimeter; 10 feet (3 meters) beyond surface walkways, patios, surface parking and utilities less than 12 inches (300 millimeters) in diameter; 15 feet (4.5 meters) beyond street curbs and main utility branch trenches; and 25 feet (8 meters) beyond constructed areas with permeable surfaces (such as pervious paving areas, stormwater retention facilities, and playing fields) that require additional staging areas to limit compaction in the constructed zone.

AND

For all projects
Survey the site to identify the following:
  1. Trees in good or excellent condition, as determined by an arborist certified by the International Society of Arboriculture (ISA).
  2. Any heritage or champion trees of special importance to the community because of their age, size, type, historical association, or horticultural value, as defined by a government forester.
  3. All trees larger than 6 inches (150 millimeters) in diameter at breast height (dbh, 4 feet 6 inches [1.4 meters] above ground).
  4. Any invasive tree species present on the site, and whether those trees threaten the health of other trees to be preserved on the site, as determined by an ISA-certified arborist.
Preserve the following trees that are also identified as in good or excellent condition:
  1. All heritage or champion trees and trees whose dbh exceeds 50% of the state champion dbh for the species.
  2. A minimum of 75% of all noninvasive trees (including the above) larger than 18 inches (450 millimeters) dbh.
  3. A minimum of 25% of all noninvasive trees (including the above) larger than 12 inches (300 millimeters) dbh if deciduous, and 6 inches (150 millimeters) dbh if coniferous.
Tree condition ratings must be based on assessment by an ISA-certified arborist using ISA approved assessment measures. Develop a plan, in consultation with and approved by an ISA-certified arborist, for the health of the trees, including fertilization and pruning, and for their protection during construction. The plan must include protective fencing located 1 foot for (300 millimeters) each 1-inch (25 millimeter) caliper from the trunk or at the tree drip line, whichever is larger, and specify that if trenching or other disturbance is necessary within the protected zone, this work must be done by hand. If disturbance includes a permanent excavation of 3 feet (900 millimeters) or deeper, the excavation must start from a point not closer than 15 feet (4.5 meters) from the tree’s drip line. If an ISA-certified arborist has determined that any trees to be preserved are threatened by invasive vegetation, develop a plan to reduce the invasive vegetation to the maximum extent possible. Stipulate in CC&R or other binding documents that the undisturbed area of the preserved trees will be protected from development in perpetuity.